The wide range of cones is suitable for use on land as well as offshore.
Mechanical jacket cone For measuring cone tip resistance and total resistance
Mechanical friction jacket cone For measuring cone tip resistance, cone tip resistance + local friction and total resistance
Elektrical cone ELC5 Cone tip area 5 cm² Friction sleeve area 75 cm²
Electrical cone ELC10 Cone tip area 10 cm² Friction sleeve area 150 cm²
Electrical cone ELC15 Cone tip area 15 cm² Friction sleeve area 275 cm²
Measuring principles: compression or subtraction. Standard geotechnical parameters: cone tip resistance qc, local friction fs. Pore-water pressure U, standard filter positions: in the cone tip, behind the cone tip, other positions on request. Inclination: in the cone tip or in separate adapter behind the cone.
Specifications (compression principle)
qc Range: 50 MPa nominal 100 MPa maximum Accuracy: standard: 0,1 MPa Class 1: 0,05 MPa (NEN 5140)
fs Range: 0,75 MPa nominal 1,5 MPa maximum
Accuracy: standard: 0,010 MPa Class 1: 0,005 MPa (NEN 5140)
U Range: 1,0 MPa nominal 2,0 MPa maximum Accuracy: standard: 0,010 MPa Class 1: 0,005 MPa (NEN 5140)
I in separate adapter Range: 15° nominal 16° maximum
Accuracy: 2°
I, X-Y in the cone tip
Range: -20° to +20° nominal (2 directions) -22° to +22° maximum (2 directions)
Accuracy: 0,5° Leaflet mechanical and electrical cones
|